29 items
-
$0.00 /
- Approx LBS/MFT: 653
- AWG Size: 4
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 964
- AWG Size: 2
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 1214
- AWG Size: 2
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 1199
- AWG Size: 1
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 1704
- AWG Size: 1
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 1414
- AWG Size: 1/0
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 1825
- AWG Size: 1/0
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 1706
- AWG Size: 2/0
- Cond. Material: Bare Copper
XLPE/PVC Unshielded Low-Voltage Industrial Power Cable Specifications
XLPE/PVC Low-Voltage Power Cable Construction:
- Conductor: 14 AWG thru 750 kcmil bare, annealed copper per ASTM B3
- Class B stranding per ASTM B8
- Insulation: Flame Retardant Cross-Linked Polyethylene (XLPE)
- Color-coded per ICEA Method 4; Individual conductors colored black with conductor number surface printed in contrasting ink
- Ground: Uninsulated bare annealed copper per ASTM B3
- Class B stranding per ASTM B8
- Jacket: Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)
- Low-Voltage Power Cable Options:
- Tinned copper conductor
- Class C stranding
- E-1 or E-2 Color Code
- Insulated ground conductors
- Overall shielded multi conductors
- Flame Retardant Ethylene Propylene Rubber (EPR) insulation
- Low-lead Hypalon Chlorosulfonated Polyethylene (CSPE) / Elastomer blend
- ICEA 1000V rated cable
- Other constructions available upon request
XLPE/PVC Low-Voltage Power Cable Ratings and Approvals:
- Voltage Rating: 600V
- Max. Temperature: 90°C wet or dry
- Industry Approvals:
- UL 44 Type XHHW-2
- UL 1277 Type TC-ER
- UL 1581
- ICEA S-95-658/NEMA WC70
- Flame Tests Approvals:
- UL 1581 VW-1
- UL 1277
- IEEE 383
- IEEE 1202
- CSA FT4
- Other Compliances:
- Meets EPA 10 CFR, Part 261 for leachable lead content per TCLP method
- OSHA acceptable
XLPE/PVC Low-Voltage Power Cable Features:
- Ripcord applied to all cables with jacket thickness of 60 mils or less
- Excellent electrical properties
- Abrasion and chemical resistant
- Sunlight and weather resistant
- Meets cold bend test at -25°C
- Meets the crush and impact requirements of Type MC
XLPE/PVC Low-Voltage Power Cable Applications:
- In free air, raceways, and direct burial applications
- In wet or dry locations
- Permitted for use in Class I, Div 2 industrial hazardous locations per NEC
- Permitted for Exposed Run 'ER' use in accordance with NEC