19 items
-
$0.00 /
- Approx LBS/MFT: 83
- AWG Size: 18
- Cond. Material: Tinned Copper
-
$0.00 /
- Approx LBS/MFT: 152
- AWG Size: 18
- Cond. Material: Tinned Copper
-
$0.00 /
- Approx LBS/MFT: 259
- AWG Size: 18
- Cond. Material: Tinned Copper
-
$0.00 /
- Approx LBS/MFT: 398
- AWG Size: 18
- Cond. Material: Tinned Copper
-
$0.00 /
- Approx LBS/MFT: 502
- AWG Size: 18
- Cond. Material: Tinned Copper
-
$0.00 /
- Approx LBS/MFT: 709
- AWG Size: 18
- Cond. Material: Tinned Copper
-
$0.00 /
- Approx LBS/MFT: 623
- AWG Size: 18
- Cond. Material: Tinned Copper
-
$0.00 /
- Approx LBS/MFT: 1008
- AWG Size: 18
- Cond. Material: Tinned Copper
FR-EPR/CPE Instrumentation Cable with Individual and Overall Shielded Pairs Specifications
FR-EPR/CPE Instrumentation Cable Construction:
- Conductor: 18 AWG and 16 AWC tinned, annealed copper per ASTM B33, Class B stranding per ASTM B8
- Insulation: Flame-Retardant Ethylene Propylene Rubber (FR-EPR) Type II
- Color-coded per ICEA Method 1: Pairs: Black and White
- Shield: Individual pairs are 100% individually shielded with aluminum/polyester in contact with stranded tinned copper drain wire.
- Jacket: Flam-Retardant Thermoplastic Chlorinated Polyethylene (CPE)
- Instrumentation Cable Options:
- Bare copper conductor
- Class C Stranding
- Overall shielded pairs Individual and Overall shielded triads
- CCTC-Cross-Linked Polyethylene (XLPE) insulation
- FREP® XL-flame retardant, thermoset Chlorinated Polyethylene (XL-CPE) jacket
- FREP® II-flame retardant, thermoplastic Low-Smoke, Zero-Halogen (LSZH) Polyolefin jacket
- FREP® 300V-UL Type PLTC
- Other constructions available upon request
FR-EPR/CPE Instrumentation Cable Ratings and Approvals:
- Voltage Rating: 600V
- Max. Temperature: 90°C wet or dry
- UL 1277 Type TC
- UL 1581
- ICEA S-82-552
- UL 1581 VW-1
- UL 1277 Flame Test
- IEEE 383
- IEEE 1202
- CSA FT-4
- ICEA T-29-520
- EPA 40 CFR, Part 261 for leachable lead content per TCLP
- OSHA acceptable
FR-EPR/CPE Instrumentation Cable Features:
- Ripcord applied to all cables with jacket thickness of 60 mils or less
- Sunlight and weather resistant
- Excellent electrical, thermal, and physical properties
- Excellent moisture resistance
- Excellent resistance to compression cuts and heat deformation
- Excellent flame resistance-burns to ash; does not exhibit thermoplastic drip
- Low coefficient of friction for easy pulling
- "Heavy-duty" rating per ICEA standards
- Excellent low-temperature cold bend characteristics
- Meets cold bend test at -40°C