36 items
-
$0.00 /
- Approx LBS/MFT: 95
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 170
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 292
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 442
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 554
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 666
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 802
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 1116
- AWG Size: 18
- Cond. Material: Bare Copper
XLPE/PVC Instrumentation Cable with Individual and Overall Shielded Pairs Specifications
XLPE/PVC Instrumentation Cable Construction:
- Conductor: 18 AWG through 16 AWG bare, annealed copper per ASTM B3, Class B stranding per ASTM B8
- Insulation: Flame retardant Cross-linked Polyethylene (XLPE)
- Color-coded per ICEA Method 1: Pairs: Black and White
- Shield: Individual and overall shielded pairs
- Individual pairs are 100% shielded with Flexfoil aluminum/polyester in contact with stranded tinned copper drain wire
- Overall shield: aluminum/polyester in contact with stranded tinned copper drain wire
- Jacket: Flame retardant and sunlight-resistant Polyvinylchloride (PVC) or Arctic-Grade PVC
- Options:
- Tinned copper conductor
- Class C Stranding
- Overall shielded pairs
- Ethylene Propylene Rubber (EPR) insulation
- In accordance with UL subject 2250 as Instrumentation Tray Cable (ITC)
- Other constructions available upon request
XLPE/PVC Instrumentation Cable Ratings and Approvals:
- Voltage Rating: 300V or 600V
- Max. Temperature: 90°C wet or dry
- UL 1581
- IEEE 383
- UL 1581 VW-1
- 300V:
- UL 13 Type PLTC
- 600V:
- UL 1277 Type TC
- ICEA S-82-552
- ICEA S-73-532
- UL 1277
- IEEE 1202
- CSA FT-4
- EPA 40 CFR, Part 261 for leachable lead content per TCLP
- OSHA acceptable
XLPE/PVC Instrumentation Cable Applications:
- Acceptable for use in free air or raceways in accordance with NEC
- Typical applications include audio, intercom, control, energy management, and alarm circuits
- In ducts, cable trays, or conduit
- In accordance with UL Subject 13 as Power-Limited Circuit Cable
- In class 3 circuits in accordance with NEC
- Permitted for use in Class 1 Division 2 industrial hazardous locations per NEC
XLPE/PVC Instrumentation Cable Features:
- Ripcord applied to all cables with jacket thickness of 60 mils or less
- Arctic-Grade PVC Cables:
- Abrasion and chemical-resistant
- Sunlight and weather resistant
- Excellent electrical properties
- Meets cold bend test at -25°C