PVC Shielded Flat Ribbon Cable (.050")

This ribbon cable consists of tinned copper conductors extruded in PVC insulation. This cable is also shielded with aluminum/polyester tape and has a black PVC jacket. This shielded cable has a maximum temperature of 105° C and is rated to 150V. This cable meets the standards for UL Style 2912 and is RoHS compliant. It is also suitable for EMI, RFI, and ESD applications.

7 items

  • RBS-28014
    $0.00 / 1000 FT
    • Approx Dimension: 0.770 ± 0.035
    • AWG Size: 28
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • RBS-28015
    $0.00 / 1000 FT
    • Approx Dimension: 0.820 ± 0.035
    • AWG Size: 28
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • RBS-28016
    $0.00 / 1000 FT
    • Approx Dimension: 0.870 ± 0.035
    • AWG Size: 28
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • RBS-28020
    $0.00 / 1000 FT
    • Approx Dimension: 1.070 ± 0.035
    • AWG Size: 28
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • RBS-28025
    $0.00 / 1000 FT
    • Approx Dimension: 1.320 ± 0.035
    • AWG Size: 28
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • RBS-28026
    $0.00 / 1000 FT
    • Approx Dimension: 1.370 ± 0.035
    • AWG Size: 28
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • RBS-28034
    $0.00 / 1000 FT
    • Approx Dimension: 1.770 ± 0.035
    • AWG Size: 28
    • Cond. Material: Tinned Copper
    Order
    Add to List

PVC Shielded Flat Ribbon Cable Specifications

Shielded Ribbon Cable Construction:

  • Uses 28 AWG tinned copper, extruded in PVC on 0.050" centers
  • Two 28 AWG drain wires are pulled in separate
  • Aluminum/Polyester tape (AL side in)
  • Shielded
  • Jacketed in black PVC (Available in other colors upon request)

Shielded Ribbon Cable Ratings and Approvals:

  • UL Listing: 2912
  • Voltage Rating: 150 Volts
  • Temperature Rating: 105°C
  • RoHS Compliant

Shielded Ribbon Cable Features and Benefits:

  • Shielded flat ribbon cable for EMI/RFI/ESD considerations
  • Two drain wires for insured grounding
  • Cable core features our popular 0.050" pitch ribbon cable for ease of termination with most IDC connectors.
  • Choose from a wide selection of conductor counts
Series No. Conductor
AWG
Stranding
Coating
Insulation Drain Shield Conductor
Resistance
O/Mft @ 20°C
Capacitance
(G-S-G) pF/ft.
Impedance
(G-S-G) (Ohms)
Jacket
(G-S-G)

RBS

28 AWG

7/36 TC

PVC

(2) 28 AWG
7/36 TC

AL/PET

67.5

20

70

Black PVC