18 items

  • PLTC-18-2PR-SPOS
    $0.00 / 1000 FT
    • Approx LBS/MFT: 42.00
    • AWG Size: 18
    • Cond. Material: Tinned Copper
    View Details
  • PLTC-18-4P-SPOS
    $0.00 / 1000 FT
    • Approx LBS/MFT: 80
    • AWG Size: 18
    • Cond. Material: Tinned Copper
    View Details
  • PLTC-18-8P-SPOS
    $0.00 / 1000 FT
    • Approx LBS/MFT: 155.00
    • AWG Size: 18
    • Cond. Material: Tinned Copper
    View Details
  • 173930-18
    $0.00 /
    • Approx LBS/MFT: 230
    • AWG Size: 18
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 /
    • Approx LBS/MFT: 306
    • AWG Size: 18
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • $0.00 /
    • Approx LBS/MFT: 375
    • AWG Size: 18
    • Cond. Material: Tinned Copper
    Order
    Add to List
  • PLTC-18-24P-SPOS
    $0.00 / 1000 FT
    • Approx LBS/MFT: 456.00
    • AWG Size: 18
    • Cond. Material: Tinned Copper
    View Details
  • PLTC-18-36P-SPOS
    $0.00 / 1000 FT
    • Approx LBS/MFT: 674.00
    • AWG Size: 18
    • Cond. Material: Tinned Copper
    View Details

XLPE/Arctic-Grade PVC Instrumentation Cable with Individual and Overall Shielded Pairs Specifications

XLPE/Arctic-Grade PVC Instrumentation Cable Construction:

  • Conductor: 18 AWG and 16 AWC tinned, annealed copper per ASTM B33, Class B stranding per ASTM B8
  • Insulation: Flame retardant Cross-Linked Polyethylene (XLPE)
    • Color-coded per ICEA Method 1: Pairs: Black and White
  • Shield: Individual pairs are 100% shielded with aluminum/polyester in contact with stranded tinned copper drain wire
  • Jacket: Flame retardant and sunlight-resistant Arctic-grade Polyvinylchloride (PVC)
  • Options:
    • Bare copper conductor
    • Class C Stranding
    • E-2 Color Code
    • CSA Rated TC for 14 AWG and larger
    • Other constructions available upon request

XLPE/Arctic-Grade PVC Instrumentation Cable Ratings and Approvals:

  • Voltage Rating: 600V
  • Max. Temperature: 90°C wet or dry
  • UL 1277 Type TC
  • UL 1581
  • CSA C22.2 No. 239 Type CIC
  • UL 1581 VW-1
  • UL 1277 Flame Test
  • CSA FT-4
  • IEEE 383
  • EPA 40 CFR, Part 261 for leachable lead content per TCLP
  • OSHA acceptable

XLPE/Arctic-Grade PVC Instrumentation Cable Features:

  • Ripcord applied to all cables with a jacket thickness of 60 mils or less
  • Sunlight and weather resistant
  • Meets CSA cold impact test at -40°C
  • Meets ICEA and CSA cold bend test at -65°C

XLPE/Arctic-Grade PVC Instrumentation Cable Applications:

  • Typical applications include industrial lighting, control, and signaling circuits
  • Primary installations include cable trays, raceways, or outdoor applications supported by a messenger wire
  • In wet or dry locations