1834
1834
$0.00
/ 100 FT
- AWG Size: 24
- Color Code Chart: 3
- Cond. Material: Tinned Copper
- Conductor Stranding: 7/32
- Drain Wire: Stranded Tinned Copper Drain Wire with each Pair
- Insul. Material: Lo-Capacitance Polypropylene (PP)
- Jacket Material: Polyvinylchloride (PVC)
- Jacket Thickness: .063
- Max. Temp: 75C
- Min. Temp: -20C
- NEC Type: CM/CMH
- No. of Pairs: 15
- No. of Strands: 7
- Nom. Cap. (C-C): 14.8
- Nom. Cap. (C-SC): 26.7
- Nom. DCR of Cond.: 26.0
- Nom. DCR of Shld.: 18.0
- Nom. Imp.: 100
- Nom. Insul. Thick. (in): .022
- Nom. O.D. of Cable (in): .743
- Shield: Individually Foil Shielded Pairs
- Shield Coverage: 100%, with 25% overlap, foil facing in
- Shield Material: Aluminum/Polyester Foil
- Strand Size: 32
- UL Style: 2493
- Vel. of Prop.: 78
- Voltage: 300