FR-EPR/XL-CPE Unshielded Multi-Conductor Control Cable (Type TC-ER) Specifications
FR-EPR/XL-CPE Control Cable (Type TC-ER) Construction:
- Conductor: 14 AWG through 500 kcmil tinned, annealed copper per ASTM B33; Class B stranding per ASTM B8
- Insulation: Flame retardant Ethylene Propylene Rubber (FR-EPR) Type II
- Color-coded per ICEA Method 4; Individual conductors colored black with conductor number surface printed in contrasting ink
- Ground: Uninsulated tinned annealed copper per ASTM B3; Class B stranding per ASTM B8
- Jacket: Cross-Linked Chlorinated Polyethylene (XL-CPE)
- FR-EPR/XL-CPE Control Cable (Type TC-ER) Options:
- 2kV version
- Bare copper conductor
- Class C stranding
- Insulated ground conductor (Cross-Linked Polyethylene (XLPE) insulation)
- Flame-Retardant Polyvinylchloride (PVC) jacket
- Thermoplastic Low-Smoke, Zero-Halogen (LSZH) jacket
- Flame-retardant Thermoplastic Chlorinated Polyethylene (CPE) Jacket
- E-1 or E-2 Color Code
- Other constructions available upon request
FR-EPR/XL-CPE Control Cable (Type TC-ER) Ratings and Approvals:
- Voltage Rating: 600V
- Max. Temperature: 90°C, wet or dry
- UL 44 Type XHHW-2
- UL 1277 Type TC-ER for 2 AWG and larger
- UL 1581
- ICEA S-95-658/NEMA WC70
- UL 1581 VW-1
- UL 1277 Flame Test
- IEEE 383
- IEEE 1202
- CSA FT4
- ICEA T-29-520
- Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
- OSHA acceptable
FR-EPR/XL-CPE Control Cable (Type TC-ER) Features:
- Ripcord applied to all cables with jacket thickness of 60 mils or less
- Excellent physical, thermal, and electrical properties
- Excellent moisture resistance
- Outstanding resistance to crush, compression cuts, and heat deformation
- Excellent flame resistance
- "Heavy-Duty" rating per ICEA standards
- Excellent low-temperature cold bend characteristics
- Meets cold bend test at -35°C
- Meets the crush and impact requirements of Type MC cable for 2 AWG and larger
FR-EPR/XL-CPE Control Cable (Type TC-ER) Applications:
- In free air, raceways, or direct burial
- In wet or dry locations
- Permitted for Exposed Run 'ER' use in accordance with NEC for 2 AWG and larger
- Permitted for use in Class I Division 2 industrial hazardous locations per NEC