This unshielded Type TC-ER cable is suitable for use in exposed runs and features a sunlight-resistant PVC jacket and nylon insulation. It is also known as a VNTC exposed run unshielded tray cable. This TC-ER cable is also suitable for use in free air, raceways, or direct burial applications, and in wet or dry conditions. It also has approval for use in Class I, Division 2 industrial hazardous locations per NEC. Control Cables with three or more conductors have approval for use as Exposed Run 'ER' use in accordance with NEC.
62 items
-
$0.00 /
- Approx LBS/MFT: 114.00
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx Dimension: .190 x .285
- Approx LBS/MFT: 36.00
- AWG Size: 18
-
$0.00 /
- Approx LBS/MFT: 56.00
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 131.00
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 209.00
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 266.00
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 371.00
- AWG Size: 18
- Cond. Material: Bare Copper
-
$0.00 /
- Approx LBS/MFT: 82.00
- AWG Size: 18
- Cond. Material: Bare Copper
Type TC-ER Unshielded Industrial Control Cable Specifications
Type TC-ER Unshielded Control Cable Construction:
- Conductor: 18 AWG thru 10 AWG fully annealed stranded tinned copper per ASTM B33
- Class B stranding per ASTM B8
- Insulation: Flame Retardant Polyvinylchloride (PVC) with clear Polyamide (nylon)
- Color-coded per ICEA Method 1; Table E-2 (Does not include white or green)
- Jacket: Flame retardant, moisture and sunlight resistant Polyvinylchloride (PVC)
- Unshielded TC-ER Cable Options:
- Tinned copper conductor
- Class C stranding
- E-1 Color Code
- Overall shielded multi conductors
- Other constructions available upon request
Type TC-ER Unshielded Control Cable Ratings and Approvals:
- Voltage Rating: 600V
- Max. Temperature: 90°C dry, 75°C wet
- Industry Approvals:
- UL 66 NEC Type TFN Conductors
- UL 1277 Type TC-ER for 3 or more conductors
- UL 1581
- ICEA S-95-658
- Flame Test Compliances:
- UL 1277
- IEEE 383
- IEEE 1202
- CSA FT4
- Other Compliances:
- Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
- OSHA acceptable
Type TC-ER Unshielded Control Cable Features:
- Ripcord applied to all cables with jacket thickness of 60 mils or less
- Outstanding sunlight, cold bend, and cold impact resistance
- Smallest cable O.D. available for suitable applications
- Long service life
- Good oil and chemical resistance
- Meets cold bend test at -20°C
- Meets crush and impact requirements of Type MC