45 items

  • General Cable Carol Brand
    323765-18
    $0.00 /
    • Approx LBS/MFT: 77
    • AWG Size: 16
    • Cond. Material: Bare Copper
    Order
    Add to List
  • General Cable Carol Brand
    323775-18
    $0.00 /
    • Approx LBS/MFT: 209
    • AWG Size: 16
    • Cond. Material: Bare Copper
    Order
    Add to List
  • General Cable Carol Brand
    133975-18
    $0.00 /
    • Approx LBS/MFT: 108
    • AWG Size: 14
    • Cond. Material: Bare Copper
    Order
    Add to List
  • General Cable Carol Brand
    134540-18
    $0.00 /
    • Approx Dimension: .230 x .370
    • Approx LBS/MFT: 57
    • AWG Size: 14
    Order
    Add to List
  • General Cable Carol Brand
    143065-18
    $0.00 /
    • Approx LBS/MFT: 130
    • AWG Size: 14
    • Cond. Material: Bare Copper
    Order
    Add to List
  • General Cable Carol Brand
    182620-18
    $0.00 /
    • Approx LBS/MFT: 173
    • AWG Size: 14
    • Cond. Material: Bare Copper
    Order
    Add to List
  • General Cable Carol Brand
    182705-18
    $0.00 /
    • Approx LBS/MFT: 87
    • AWG Size: 14
    • Cond. Material: Bare Copper
    Order
    Add to List
  • General Cable Carol Brand
    182715-18
    $0.00 /
    • Approx LBS/MFT: 236
    • AWG Size: 14
    • Cond. Material: Bare Copper
    Order
    Add to List

PE/PVC/PVC Unshielded Multi-Conductor Industrial Control Cable Specifications

PE/PVC/PVC Unshielded Multi-Conductor Control Cable Construction:

  • Conductor: 18 AWG through 10 AWG bare, annealed copper per ASTM B3
    • Class B stranding per ASTM B8
  • Insulation: Clear Polyethylene (PE)
  • Conductor Jacket: Color-coded Polyvinyl Chloride (PVC)
    • Color-coded per ICEA Method 1; Table E-1 (includes white and green)
  • Cable Core: Conductors are cabled with non-hygroscopic fillers as necessary, and an overall binder tape
  • Overall Jacket: Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC)
  • PVC Control Cable Options:
    • Tinned copper conductor
    • Class C stranding per ASTM B8
    • Insulated or uninsulated ground conductors
    • Copper tape shield or aluminum/polymer tape shield with tinned copper drain wire over the cable core
    • Bare or tinned copper braided basket weave shield
    • Duralox® aluminum or galvanized steel interlocked armor
    • Intergrabon® Moisture Barrier system
    • Corrugated copper tape shield longitudinally applied

PE/PVC/PVC Unshielded Multi-Conductor Control Cable Ratings and Approvals:

  • Voltage Rating: 600V
  • Max. Temperature: 75°C
  • ICEA S-73-532
  • Meets EPA 10 CFR, Part 261 for leachable lead content per TCLP method

PE/PVC/PVC Unshielded Multi-Conductor Control Cable Applications:

  • For applications where environmental factors require cable characteristics including flame-retardance, resistance to chemicals, abrasion, and resistance to the harmful effects of sunlight and weather.
  • It may be installed in ducts, cable trays, conduits, Class I, Division 2 industrial hazardous locations, or continuous rigid cable supports.