The Lapp 490 CP Cable is a control cable suitable for use in machine tool equipment, handheld controls, submersible applications, and applications where cables can be cut or damaged by sharp objects. This cable features an overall foil tape with drain wire and tinned copper braid shield for EMI and RFI protection. This cable's rugged PUR jacket resists cuts, nicks, and abrasion.

35 items

  • 401802CP
    $0.00 /
    • Approx LBS/MFT: 62
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    401803CP
    $0.00 / 1000 FT
    • Approx LBS/MFT: 71
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    401804CP
    $0.00 /
    • Approx LBS/MFT: 82
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    401805CP
    $0.00 /
    • Approx LBS/MFT: 95
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    401807CP
    $0.00 /
    • Approx LBS/MFT: 117
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    401809CP
    $0.00 /
    • Approx LBS/MFT: 139
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    401812CP
    $0.00 /
    • Approx LBS/MFT: 176
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    401818CP
    $0.00 / 1000 FT
    • Approx LBS/MFT: 240
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List

Lapp 490 CP Control Cable Specifications

490 CP Cable Construction:

  • Conductors: Finely stranded bare copper (Class 5 fine wire)
    • *2 conductor constructions do not include ground
  • Insulation: Specially blended PVC
  • Color Code: Black with white numbers, plus green/yellow ground
  • Shield: Overall foil tape wrap with drain wire; Overall tinned copper braid (85% coverage)
  • Jacket: Specially formulated gray Polyurethane

490 CP Cable Ratings and Approvals:

  • Temperature Range:
    • For flexible use: -10°C to +80°C
    • For stationary use: -20°C to +80°C
  • Minimum Bend Radius - Shielded: 6 x cable diameter
  • Nominal Voltage: 600V
  • Testing Voltage: 2000V
  • UL: AWM 20234
  • Attributes:
    • UL Oil Res I/II
    • Sunlight resistant
    • NFPA 79 2012
  • CSA: AWM I/II A/B FT1
  • CE and RoHS Compliant