- Approx LBS/MFT: 27.103
- AWG Size: 20
- Cond. Material: Tinned Copper
- Conductor Stranding: 10/30
- CSA Type: CSA I/II A/B FT1
- Insul. Material: Modified Polyphenylene Ether (mPPE)
- Jacket Material: Modified Polyphenylene Ether (mPPE)
- Jacket Thickness: 0.035 in.
- Max. Temp: 105C
- Min. Temp: - 40C
- No. of Cond.: 4
- No. of Strands: 10
- Nom. Insul. Thick. (in): 0.0095
- Nom. O.D. (in): 0.207
- Shield Material: Unshielded
- Strand Size: 30
- UL Style: UL AWM 21819 (600 V, 105C), UL AWM 21492 (300 V, 80C)
- Voltage: 600
Alpha EcoGen 79003 20 Gauge Unshielded Cable
79003 Alpha 20 gauge EcoGen is a high performance eco-friendly alternative to traditional cables and meet UL AWM 21819 (600 V, 105°C), UL AWM 21492 (300 V, 80°C) standards. 79003 has a Modified Polyphenylene Ether (mPPE) jacket and Tinned Copper conductor with an operating temperature range of - 40°C to 105°C. The Tinned Copper conductor with 10/30 conductor stranding is made for increased performance. The insulation material is Modified Polyphenylene Ether (mPPE) with a nom. thickness of 0.0095. All EcoCable products contain no halogens, phthalates or heavy metals