The Lapp Power Multi Cable is a control cable suitable for use in power cords, appliances, factory installations, and power hook-ups. This composite cable features a durable jacket for long performance life and uses in hazardous industrial locations. It is sunlight and oil resistant, as well as suitable for use in direct burial applications.

20 items

  • 611803CRF
    $0.00 /
    • Approx LBS/MFT: 62
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    611804
    $0.00 /
    • Approx LBS/MFT: 71
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    611805
    $0.00 /
    • Approx LBS/MFT: 82
    • AWG Size: 18
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    611603
    $0.00 /
    • Approx LBS/MFT: 75
    • AWG Size: 16
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    611604
    $0.00 /
    • Approx LBS/MFT: 88
    • AWG Size: 16
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    611605
    $0.00 /
    • Approx LBS/MFT: 104
    • AWG Size: 16
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    611607
    $0.00 / 1000 FT
    • Approx LBS/MFT: 132
    • AWG Size: 16
    • Cond. Material: Bare Copper
    Order
    Add to List
  • Lapp Cable
    611612
    $0.00 /
    • Approx LBS/MFT: 225
    • AWG Size: 16
    • Cond. Material: Bare Copper
    Order
    Add to List

Lapp POWER MULTI Control Cable Specifications

POWER MULTI Cable Construction:

  • Conductors: Finely stranded bare copper (Class 5 fine wire)
  • Insulation: Specially blended PVC/Nylon
  • Color Code:
    • 3 Conductor: black, white, green/yellow
    • 4 Conductor: black, white, red, green/yellow
    • 5 Conductor: black, white, brown, red, green/yellow
    • 7 Conductor and Higher: black with white numbers, plus green/yellow ground
  • Jacket: Specially formulated black oil and chemical resistant elastomeric alloy

POWER MULTI Cable Ratings and Approvals:

  • Temperature Range:
    • UL/CSA: -25°C to +90°C
    • For flexible use: -5°C to +90°C
    • For stationary use: -40°C to +105°C
  • Minimum Bend Radius (for installation): 4 x cable diameter
  • Nominal Voltage (UL/CSA TC/STOOW): 600V
  • Test Voltage: 2000V
  • UL: TC-ER per UL 1277; STOOW per UL 62
  • Attributes:
    • UL Oil Res I/II
    • 75°C Wet; 90°C Dry
    • Sunlight resistant
    • Direct burial
    • NFPA 79 2012
  • NEC: Class 1 Division 2 per NEC Article 501
  • Canada:
    • c(UL) CIC/TC FT4
    • c(UL) STOOW
    • CSA AWM I/II A/B FT4
  • CE and RoHS compliant